Adding Minimum Standard Deviation

You can set the threshold of the standard deviation to a minimum value. The minimum standard deviation set point is 3 cm during the whole survey.

Changing for a minimum value of 1 cm is recommended if:

> system is rigidly fixed
> lever arm are precisely measured (<1cm)
1. Right click on the GPS parameter and select Add Minimum sd. The Minimum sd parameters are displayed.

2. Click on the right of the Axis field and select an axis.
> All
> Horizontal
> Vertical
3. Click on the right of the Value field. Enter the corresponding value.
4. Click on the right of the From and To fields. Enter the corresponding values.