Entering Values

Physical Units

When entering a physical unit, you can enter the value and indicate the unit of measurement.

For example, for a distance you can enter "1.5 m”, “150 cm”, “4.921 ft” or “1.5”.

If no unit is specified, the unit used is the default unit defined in the customer settings.

 

Time

You can enter a time data either in absolute or relative mode:

> In absolute mode, enter the date and time as YYYY/MM/DD, hh:mm:ss.sss, DD/MM/YYYY, hh:mm:ss.sss or MM/DD/YYYY hh:mm:ss.sss (the default format is defined in the customer settings).
> In relative mode, enter a period with respect to the origin of the data to be processed in the form J hh:mm:ss.sss or directly in seconds, minutes or hour (123.5 s, 2.004 min, 0.057 h)

When entering a period (From, To), if you do not specify the start, the period starts at the origin of the data to be processed. If the end date is not specified, the period stops at the end of the data to be processed.

 

Geographical Position

The typing in Delph INS Subsea is adaptive and is compatible with a series of data formats. For example, the following ways formats are supported to display latitude inside Delph INS Subsea:

> 48.89734
> 48°34.6789
> 48°34’27.4567

 

Sign

The sign can be given by “+” and “-“ before the value or with “N”, “S”, “E” or “W” before or after the value. A “ “ can be present also between the sign and the value.

 

Separator

The separators can be:

> Decimal separator “,” or “.”
> Degrees separator “°”, “d”, “D” or “ “
> Minutes separator “’” , “m”, “M”, or “ “

 

Data Format

For the data format, you can define:

> Precision: number of figures after the comma
> Sign: “+“, “-“, “N“, “S“, “E“, “W“
> Degrees separator: “°”, “d”, “ “
> Minute separator: “’” , “m”, “ “

When typing the additional zeroes are not taken into account but they are systematically used during value formatting.

During conversion from text format to numerical format, no precision rounding is performed.

 

Key Shortcuts

Use the key shortcuts to optimize the use of Delph INS Subsea:

> [F2]: switches the selected item into edition mode
> [Enter]: validates the entered value
> [Esc]: cancels the editing